Please use this identifier to cite or link to this item:
https://apo.ansto.gov.au/dspace/handle/10238/700
Title: | Optimisation of an epithermal beam in HIFAR for boron neutron-capture therapy |
Authors: | Harrington, BV |
Keywords: | HIFAR Reactor Epithermal neutrons Boron isotopes Neutron capture therapy |
Issue Date: | Aug-1987 |
Publisher: | Australian Nuclear Science and Technology Organisation |
Citation: | Harrington, B. V. (1987). Optimisation of an epithermal beam in HIFAR for boron neutron-capture therapy. (ANSTO/E662). Lucas Heights, NSW: Australian Nuclear Science and Technology Organisation. |
Abstract: | A calculational study was undertaken to investigate the feasibility of developing an epithermal beam in the 10H horizontal facility of the HIFAR research reactor suitable for boron neutron-capture therapy of deep-seated metastatic melanoma. The filters considered were Al Al/S and AlF-3. Dose intensities and therapeutic gains in a phantom were calculated to determine optimum neutron and gamma filter lengths. |
Gov't Doc #: | 710 |
URI: | http://apo.ansto.gov.au/dspace/handle/10238/700 |
ISBN: | 0642598665 |
ISSN: | 10307745 |
Appears in Collections: | Scientific and Technical Reports |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ANSTO-E-662.pdf | 1.57 MB | Adobe PDF | ![]() View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.